M-SURE Digital Calipers User Guide

Accurate, reliable and built for professionals – the M-SURE Digital Calipers are precision tools engineered to deliver consistent measuring performance. Whether you're in a workshop, lab, or manufacturing environment, this guide will help you get the most from your digital caliper.

Getting Started: First Use Instructions

Before using your M-SURE Caliper:

  • Wipe the caliper with a clean cloth moistened with cleaning oil.
  • Treat the instrument with care – it’s a precision measuring tool, not a robust mechanical device.
  • The pre-installed battery is for factory testing and may not last long; consider replacing it for optimal performance.
  • Avoid exposure to moisture, extreme heat, cold, or direct sunlight.
  • Never apply voltage or attempt to engrave the device electrically.
  • Remove the battery if the caliper will be unused for an extended period.

Operating the Caliper

Basic Measuring Steps

Check & Clean: Ensure the jaws and measuring surfaces are clean.

Power On: Switch on the device.

Zero the Display: Loosen the locking screw and fully close the jaws. If the display doesn’t read “0.00”, press the ZERO button.

Select Units: Use the in/mm button to toggle between metric and imperial units.

Take Measurement: Gently place the caliper onto your workpiece – no excessive force is required.

Types of Measurements

External Measurement: Use the external jaws.

Internal Measurement: Use the internal jaws.

Depth Measurement: Utilise the depth rod at the end of the beam.

Step Measurement: Use the rear step feature behind the jaws.

Battery Replacement Instructions

  1. Insert the key into the battery cover.
  2. Gently twist to unlock (do not use excessive force).
  3. Remove the battery cover.
  4. Extract the battery – a magnet-tipped tool may help.
  5. Locate the spring contact inside the battery compartment.
  6. Insert the new battery with its edge against the contact.
  7. Press down on the opposite edge to seat it.
  8. Align the battery cover lugs with the slots on the caliper.
  9. Twist to lock the cover back into place.

Function Buttons Overview

Function Button Location Purpose
ZERO/SET Front Panel Resets the measurement value to 0.00 mm
in/mm Front Panel Toggles between inches and millimetres
PRE+ / PRE- (MS-222 models) Adjusts preset value
ABS (ABS models) Switches between Absolute and Incremental modes

 

Calipers with Preset Function (MS-222 Models Only)

  1. In INC (incremental) mode, press and hold ZERO/SET until “SET” flashes.
  2. Use PRE+ or PRE- to enter your preset value.
  3. Press ZERO/SET again to confirm.
  4. To recall this preset, press ZERO/SET again (INC mode only).

Zeroing the Caliper

  • Close the jaws completely.
  • Press the ZERO button until the display reads "0.00 mm"

Using the ABS (Absolute) Function

  1. Close the caliper and press ZERO to set the reference point.
  2. Measure a workpiece (e.g. 10.00 mm).
  3. Press ABS to switch to incremental mode.
  4. Perform relative measurements.
  5. Press ABS again to return to absolute mode.

Troubleshooting Common Issues

Problem Cause Solution
Flashing Display Low battery / poor contact Replace battery / clean contacts
No Display Dead battery Replace battery
Erratic or Frozen Display Dirt on beam or head Wipe clean, replace battery if needed
Incorrect Readings Low voltage, excessive force Replace battery / operate with less force
Non-zero Reading When Closed Needs zeroing Press ZERO button

 

Final Notes

  • Always store the caliper in a dry, cool place.
  • Never use solvents or harsh chemicals for cleaning – stick to a soft cloth and cleaning oil.

Keep the battery removed during long periods of inactivity to prevent corrosion.

M-SURE Digital Calipers User Guide